This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

UK rocket motor company fined for safety failings

12 July 2016

An engineering company in Worcestershire, has been fined more than £380,000 for safety failings. Worcester Crown Court heard how an employee of Roxel (Rocket Motor) Limited was inspecting a rocket motor for damages received during the manufacturing process. The UK Health and Safety Executive reported that the emplyee used a fibre optic light to illuminate a conduit on the ‘charge’ of the motor.

The propellant ignited by the heat from the light, but no one was injured.

The charge burned for about 10 seconds sending flames and gases out of both ends of the ‘charge’ until it burnt out. The room where the ignition occurred was set on fire. Also present in that room were four explosives charges and a Vulcan rocket motor, there was also a further 230kg of explosive charges in the magazine that is next door to the room, which still had the magazine doors open. Two employees were working in the room and an agency worker was present in the magazine when the ignition occurred. It was foreseeable that other propellants and charges in the room and magazine could have been ignited by the Titus charge and subsequent fires.

At the time of the incident the company did not know what explosives were in the building and could not inform the emergency services as to the level of risk. The potential to cause harm was great due to excessive explosives material being present in the building and the number of people present nearby including the emergency services.

It took the company well over an hour for the them to understand the hazards present and react to the situation, The on-site emergency plan was not made available to the Fire and Rescue Services, meaning they were put at risk.

An investigation by the Health and Safety Executive (HSE) into the incident which occurred on 16 November 2012 found that there was a lack of assessments of the risks and no safe system of work in place. The emergency plan was not implemented.

Roxel (UK Rocket Motors) Limited, of Summerfield Lane, Summerfield, Kidderminster, Worcestershire, pleaded guilty to breaching Sections 2(1) and 3(1) of the Health and Safety at Work etc. Act 1974, and Regulation 12 of the Control of Major Accident Hazards 2015, and was fined £386,000 and ordered to pay costs of £60,000.


Contact Details and Archive...