This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Worker suffers “battlefield” injuries in UK explosion

03 March 2014

A worker had to have both legs amputated and now has restricted movement in his arms following an explosion at a factory in Worcestershire. The employee at Filtration Service Engineering, Kidderminster, was hit by debris on 8 December 2011 when a 335-litre vessel exploded as it was being pressure tested. 

The scene after the blast - Photo: HSE
The scene after the blast - Photo: HSE

The extent of the explosion tore the two parts of the vessel apart, with one part hitting the worker and forcing him into a cabinet against a wall. He was hospitalised for several months and had to have both legs amputated. He also suffered head injuries and has severely restricted movement in his arms, which have been repaired with metal plates.

An investigation by HSE found that Filtration Service Engineering was testing the vessel as there were concerns about the quality of the welding. However, instead of simply filling it with water, the firm decided to use compressed air.

Worcester Crown Court heard on 20 February that the factory's compressed air supply was directly connected to one of the vessel's openings. A valve, which could be manually opened and closed, and a pressure gauge were installed and the vessel filled with compressed air. The pressure built up to such an extent that eventually the vessel exploded.

The company was fined £30,000 and ordered to pay £15,325 in costs after pleading guilty to breaching section 2(1) of the HSWA 1974.

 Following the hearing, HSE inspector, Ed Fryer, said: "The injuries sustained in the incident were more akin to those sustained on a battlefield. The vessel exploded like a bomb during the course of a normal working day, and everyone in the factory was at risk from the operation because no measures were put in place to protect them.

 "Pneumatic testing is a dangerous activity and significant planning is required to ensure the risks are managed.  The management of health and safety in this factory was woefully inadequate and simple measures could have been implemented to prevent the incident from happening.

 "An assessment of the risks involved in pneumatic pressure testing should have identified that air was not a suitable testing medium. The test could have been carried out by simply filling the vessel with water. It is a miracle that more people were not injured and that nobody lost their life."