This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Baseefa Ltd

HSE issues Lokring pipe connector Safety Alert

15 April 2015

On April 14, the UK Health & Safety Executive (HSE) Energy Division (Offshore) issued a Safety Alert highlighting the issue of chloride stress corrosion cracking which has been found to affect stainless steel (grade 316/316L) Lokring pipe connectors. The cracking has occurred in the driver / swage ring section of the connector as shown in the image.

Dutyholders have found cracks in the driver ring section of stainless steel Lokring pipe connectors. This component is subject to tensile hoop stress and when exposed to a chloride-containing environment (such as marine and coastal areas or saltwater deluge systems) can be affected by chloride stress corrosion cracking.

All the cracks found to date have been in unpainted stainless steel pipe connectors. However, the crevice in the connector (as shown above) presents a potential initiation site by localised corrosion, so painting may not guarantee elimination of the problem.

Visual inspection and dye penetrant inspection can only find cracks that are surface breaking. Radiography has identified internal cracks that are not yet visible. Crack propagation and failure could therefore occur even where no cracks have been seen at the surface.

The driver ring is essential in maintaining the integrity of the connector. Cracking of this ring therefore presents a serious loss of containment risk.

HSE research report RR902 Chloride stress corrosion cracking in austenitic stainless steel describes the process of chloride stress corrosion cracking in austenitic stainless steel and how to assess susceptibility to this degradation mechanism.

Action required:

Dutyholders should identify where stainless steel Lokring connectors are in service in a chloride-containing environment, and remove from service where failure could present a safety risk.

In order to reduce the risk in the most timely manner, the removal of connectors should be prioritised by the consequence of failure, time in service and most corrosive environment (eg temperature, presence of chlorides etc) as described in RR902.